Skip to Main Content (Press Enter)

Logo UNIME
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Competenze e Professionalità
Logo UNIME

|

UNIFIND - Competenze e Professionalità

unime.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Comparison of Refractometric and Biuretic Methods for the Assay of Total Protein in Horse Serum and Plasma Under Various Storage Conditions

Articolo
Data di Pubblicazione:
2018
Abstract:
This study aimed to investigate the differences in assessment of total proteins between the use of refractometric and biuretic methods in equine serum and plasma samples and to test the validity of the two methods at different storage conditions. Serum and plasma total proteins concentration from 60 nonhemolytic and nonlipemic equine blood samples was assessed using refractometric and biuretic methods. On serum and plasma samples albumin, triglycerides, cholesterol, glucose, total bilirubin, and fibrinogen values were also evaluated. Samples were analyzed immediately after centrifugation (T0), refrigerated at 4°C and analyzed after 24 hours (T1) and 48 hours (T2), stored under refrigeration at 4°C, and after 1 week (T3) of storage at −20°C. No statistically significant effect of method (P >.05) on serum and plasma total proteins levels was found. A significant effect of storage condition (P <.01) and sample type (P <.05) was revealed on total proteins values. A significant effect of storage condition (P <.01) was found on albumin, triglycerides, glucose, and total bilirubin values measured in both serum and plasma samples. Significant lower fibrinogen values were found at T0 with respect to T1, T2, and T3 and at T1 and T2 with respect to T3 (P <.001). The use of refractometer for total proteins measurement in equine serum or plasma samples without any visible abnormality was sufficiently reliable, providing an inexpensive and rapid alternative to biuret method. The present study suggests that storage conditions of serum/plasma samples are important preanalytical variables, which may considerably affect the determination of the most frequently texted parameters in the equine species.
Tipologia CRIS:
14.a.1 Articolo su rivista
Keywords:
Biuret; Refractometer; Serum/plasma; Storage condition; Total protein; Equine
Elenco autori:
Arfuso, Francesca; Giannetto, Claudia; Rizzo, Maria; Giudice, Elisabetta; Fazio, Francesco; Piccione, Giuseppe
Autori di Ateneo:
ARFUSO Francesca
FAZIO Francesco
GIANNETTO Claudia
GIUDICE Elisabetta
PICCIONE Giuseppe
Link alla scheda completa:
https://iris.unime.it/handle/11570/3124089
Pubblicato in:
JOURNAL OF EQUINE VETERINARY SCIENCE
Journal
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.4.5.0