Comparative safety, efficacy, and predictors of complete occlusion of flow diverter devices in the treatment of unruptured distal anterior cerebral artery aneurysms

Articolo
Data di Pubblicazione:
2026
Abstract:
Background: Flow diverters (FDs) are increasingly used for cerebral aneurysms, including distal anterior cerebral artery (DACA) aneurysms, but comparative data between devices in this challenging location are limited. Objective: To compare the safety and efficacy of Pipeline, Silk Vista Baby (SVB), and FRED Jr. FDs for unruptured DACA aneurysms and identify predictors of complete occlusion. Methods: We retrospectively analyzed 166 patients treated with FDs at 39 centers in 14 countries (2018–2022) from the CRETA registry. Outcomes included aneurysm occlusion (O’Kelly–Marotta [OKM] scale), complications, retreatment, modified Rankin Scale (mRS) scores, and independent predictors of complete occlusion using multivariable Cox regression. Results: Aneurysms were predominantly saccular and located on the pericallosal artery. Complete occlusion (OKM D) was achieved in 73%, and neck remnants (OKM C) in 12%, with no differences across devices. Ischemic complications occurred in 11% (mostly asymptomatic), hemorrhagic complications in 5%, and in-stent stenosis in 17%. Retreatment was performed in 1.3%. At last follow-up, 98% had mRS ≤ 2. Independent predictors of complete occlusion were female sex (HR 1.85), asymptomatic presentation (HR 1.79), smaller aneurysm neck (HR 0.83/mm), radial access (HR 2.20), and aspirin plus ticagrelor therapy (HR 1.84); device type was not predictive. Conclusion: Pipeline, SVB, and FRED Jr. FDs show similar safety and efficacy for unruptured DACA aneurysms. Complete occlusion is influenced by clinical and procedural factors, supporting individualized device selection.
Tipologia CRIS:
14.a.1 Articolo su rivista
Keywords:
Aneurysm occlusion; Distal anterior cerebral artery aneurysms; Endovascular treatment; Flow diverter devices
Elenco autori:
Salim, H. A.; Scarcia, L.; Clarencon, F.; Hajjeh, O.; Daraghma, M.; Simonato, D.; Li, Y. -L.; Shotar, E.; Premat, K.; Jabbour, P.; Tjoumakaris, S. I.; Gooch, R. M.; Psychogios, M.; Ntoulias, N.; Sporns, P.; Puri, A. S.; Singh, J.; Kuhn, A. L.; Hassan, A. E.; Algin, O.; Mohlenbruch, M. A.; Hohenstatt, S.; Russo, R.; Bergui, M.; Goren, O.; Kole, M. J.; Bankole, N. D. A.; Bibi, R.; Boulouis, G.; Morimoto, T.; Sakakibara, F.; Pop, R.; Juravle, C.; Ho, J. W. K.; Ferrario, A.; Lereis, V. P.; Cooper, J.; Gandhi, C. D.; Salsano, G.; Castellan, L.; Consoli, A.; Sgreccia, A.; Raz, E.; Chung, C.; Burel, J.; Papagiannaki, C.; Rasheed, U.; Hassan, K. M. B.; Tao, H.; Ji, Z.; Rautio, R.; Sinisalo, M.; Ruggiero, M.; Lafe, E.; Da Ros, V.; Bellini, L.; Gabrieli, J. D.; Causin, F.; Levitt, M. R.; Carroll, K.; Abecassis, Z.; Caragliano, A. A.; Vinci, S. L.; Bellanger, G.; Cognard, C.; Marnat, G.; Saleille, L.; Limbucci, N.; Capasso, F.; Piano, M.; Rollo, C.; Guedon, A.; Arpaia, F.; Romi, A.; Di Caterino, F.; Biondi, A.; Kalsoum, E.; Vyval, M.; Guenego, A.; Nguyen, T.; Abdalkader, M.; Agripnidis, T.; Patel, A. B.; Pereira, V. M.; Fuschi, M.; Pedicelli, A.; Yedavalli, V.; Wintermark, M.; Alexandre, A. M.; Dmytriw, A. A.
Autori di Ateneo:
VINCI Sergio Lucio
Link alla scheda completa:
https://iris.unime.it/handle/11570/3358309
Pubblicato in:
NEUROLOGICAL SCIENCES
Journal
NEUROLOGICAL SCIENCES