Skip to Main Content (Press Enter)

Logo UNIME
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Competenze e Professionalità
Logo UNIME

|

UNIFIND - Competenze e Professionalità

unime.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Optimal Seismic Response Control of Adjacent Buildings Coupled with a Double Mass Tuned Damper Inerter

Capitolo di libro
Data di Pubblicazione:
2022
Abstract:
Adjacent buildings are exposed to a high risk of pounding against each other during seismic events. In recent strong earthquakes events, the separation gap has been found to be insufficient to prevent structural damage related to pounding phenomena. The inerter-based tuned mass damper has been validated as an effective, lightweight passive control device by incorporating the inerter into a conventional tuned mass damper (TMD). The proposed system's optimal design is achieved using a constrained optimization problem based on the Grey Wolf Optimizer (GWO) algorithm. This numerical study investigates the capability of reducing the pounding risk of inertially connected tuned mass dampers (TMDs). The presented system connects two high-rise adjacent buildings as a novel seismic protection system. The optimal design of the proposed system is conducted through a constrained optimization problem via a Grey Wolf Optimizer (GWO) algorithm, wherein the pounding gap distance of the two high-rise adjacent buildings is selected as performance index. Optimal results obtained are critically analyzed and compared. For comparison purposes, two separate TMDs are mounted on the rooftop of each of the adjacent buildings, and the two systems are optimized independently under the constraint of the same total mass. Performance of these independent TMDs is evaluated to compared to that of inertially connected ones using a large number of ground motions selected from a set of 462 ground motion records. The main response parameters of interest are the minimum seismic gap for pounding mitigation, along with inter-storey drift. When the two buildings have different natural frequencies, the results reveal that the suggested new device outperforms the non-connected TMDs system.
Tipologia CRIS:
14.b.1 Contributo in volume (Capitolo o Saggio)
Keywords:
Adjacent buildings; Grey wolf optimizer; Inerter; Pounding; Structural optimization; Tuned mass damper; Tuned mass damper inerter
Elenco autori:
Djerouni, S.; Abdeddaim, M.; Elias, S.; De Domenico, D.; Rupakhety, R.
Autori di Ateneo:
DE DOMENICO Dario
Link alla scheda completa:
https://iris.unime.it/handle/11570/3231471
Titolo del libro:
Optimization of Tuned Mass Dampers. Studies in Systems, Decision and Control,
Pubblicato in:
STUDIES IN SYSTEMS, DECISION AND CONTROL
Series
  • Dati Generali

Dati Generali

URL

https://link.springer.com/chapter/10.1007/978-3-030-98343-7_6
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 25.10.4.0