dB/dt Evaluation in MRI Sites: Is ICNIRP Threshold Limit (for Workers) Exceeded?

Articolo
Data di Pubblicazione:
2018
Abstract:
The Directive 2013/35/EU establishes standards for workers exposed to static and time varying magnetic fields. These limits are based on ICNIRP guidelines expressed in terms of the electric field induced in the body. The complexity of this measurement led to theoretical models being developed. In this study, the experimental evaluation included varying magnetic field exposures for two classes of MRI workers. The measurements are conducted on four different MRI Systems including one 0.35 T, two 1.5 T, and one 3.0 T. Pocket magnetic dosimeters were used and it was carried out during routine conditions, emergency conditions, and cold-head maintenance/substitution. The acquired data has been processed and the corresponding dB/dt curves have been computed as the first time derivative of the dataset. The weighted peak approach was also implemented for the compliance assessment with regulatory limits. The dB/dt peak values have been compared with the reference level (RL) proposed by ICNIRP. The results show that the RL always exceeds during measurements on the 3.0 T scanner and sometimes on 1.5 T. In light of the foregoing, the diffusion of ultra-high field MRI scanners involves the introduction of behavioral rules that could be more useful than a numerical action level.
Tipologia CRIS:
14.a.1 Articolo su rivista
Keywords:
MRI safety, MRI workers exposure, Static magnetic field, Time-varying magnetic field
Elenco autori:
Acri, Giuseppe; Inferrera, Patrizia; Denaro, Lucia; Sansotta, Carlo; Ruello, Elisa; Anfuso, Carmelo; Salmeri, Francesca Maria; Garreffa, Girolamo; Vermiglio, Giuseppe; Testagrossa, Barbara
Autori di Ateneo:
ACRI Giuseppe
DENARO Lucia
Gruppo Lab Fisica Ambientale - Sanitaria
RUELLO Elisa Venera
SANSOTTA Carlo
TESTAGROSSA Barbara
Link alla scheda completa:
https://iris.unime.it/handle/11570/3127335
Link al Full Text:
https://iris.unime.it//retrieve/handle/11570/3127335/308653/dB_dt%20Evaluation%20in%20MRI%20Sites_Is%20ICNIRP%20Threshold.pdf
Pubblicato in:
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH
Journal
  • Dati Generali

Dati Generali

URL

https://www.mdpi.com/1660-4601/15/7/1298
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 25.10.4.0