Analysis of polyphenols and methylxantines in tea samples by means of nano-liquid chromatography utilizing capillary columns packed with core-shell particles
Articolo
Data di Pubblicazione:
2012
Abstract:
In this study, a rapid separation of eleven polyphenols and three methylxanthines was obtained by means of nano-liquid chromatography (nano-LC), employing a 100 mu m I.D. capillary column packed with C18 core-shell particles (2.7 mu m) for 10 cm. All compounds were baseline resolved with a step gradient elution in less than 15 min. The developed analytical method was validated and the resulting RSD% for intra-day and inter-day repeatability, related to retention time, retention factor and peak area, were below 5.1 and 5.7%. LOD and LOQ values corresponded to 0.300 and 0.625 mu g/mL, while linearity range assessed gave R-2 no lower than 0.990. Then, the method was used to determine studied compounds in tea extracts. Further, the nano-LC system was coupled with a mass spectrometer to confirm the components present in real samples. Finally the results were compared with those obtained using a capillary column (100 mu m I.D. x 10 cm) packed with C18 sub-2 mu m particles, applying the same nano-LC experimental conditions. (C) 2012 Elsevier B.V. All rights reserved.
Tipologia CRIS:
14.a.1 Articolo su rivista
Keywords:
TANDEM MASS-SPECTROMETRY; PHENOLIC-COMPOUNDS; FUSED-CORE; CATECHINS; SEPARATION; HPLC; CAFFEINE
Elenco autori:
C., Fanali; A., Rocco; Z., Aturki; Mondello, Luigi; S., Fanali
Link alla scheda completa:
Pubblicato in: