Skip to Main Content (Press Enter)

Logo UNIME
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Competenze e Professionalità
Logo UNIME

|

UNIFIND - Competenze e Professionalità

unime.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Cyclic variation in ultrasonic myocardial integrated backscatter is due to phasic changes in the number of patent myocardial microvessels

Articolo
Data di Pubblicazione:
2006
Abstract:
Objective. We tested the hypothesis that the cyclic variation in ultrasonic myocardial integrated backscatter (IBS) is due to cardiac contraction-induced changes in the number of patent myocardial microvessels. Methods. We performed experiments in open-chest dogs in which we increased the number of patent myocardial microvessels without changing cardiac contraction. We achieved this either by direct intracoronary administration of adenosine (group 1; n = 10) or by producing a noncritical coronary stenosis (group 2; n = 7). Results. At baseline, IBS was lowest in systole and highest in diastole. This cyclic variation in IBS was closely associated with the phasic changes in myocardial blood volume that were measured with myocardial contrast echocardiography During adenosine administration, the diastolic IBS increased from -18.8 ± 6.5 to -17.5 ± 6.1 dB (P = .002), with an associated increase in the difference between the systolic and diastolic IBS from 3.8 ± 1.1 to 4.6 ± 1.0 dB (P = .009). After a non-critical stenosis was produced, diastolic IBS also increased from -26.6 ± 8.3 to -25.2 ±7.3 dB (P = .001), with an associated increase in the difference between the systolic and diastolic IBS from 3.7 ± 1.2 to 5.0 ± 1.0 dB (P = .02). No change in IBS was noted in the bed that did not receive adenosine or the bed that had a stenosis. Conclusions. The variation in IBS during the cardiac cycle is closely associated with the phasic changes in myocardial blood volume seen during cardiac contraction. When the number of patent myocardial arterioles is increased via adenosine or placement of a noncritical stenosis, diastolic IBS increases with a concomitant increase in IBS cyclic variation. These results may have important clinical applications for the noninvasive diagnosis of noncritical coronary stenosis at rest. © 2006 by the American Institute of Ultrasound in Medicine.
Tipologia CRIS:
14.a.1 Articolo su rivista
Keywords:
Cardiac contraction; Cyclic variation; Integrated backscatter; Myocardial blood volume; Adenosine; Animals; Contrast Media; Coronary Stenosis; Dogs; Elasticity; Fluorocarbons; Microcirculation; Models, Cardiovascular; Myocardial Contraction; Coronary Circulation; Echocardiography
Elenco autori:
Micari, A.; Pascotto, M.; Jayaweera, A. R.; Sklenar, J.; Goodman, N. C.; Kaul, S.
Autori di Ateneo:
MICARI Antonio
Link alla scheda completa:
https://iris.unime.it/handle/11570/3194799
Pubblicato in:
JOURNAL OF ULTRASOUND IN MEDICINE
Journal
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.5.0.0