  1. Pubblicazioni

Cooled tip radiofrequency ablation of benign thyroid nodules: preliminary experience with two different devices

Articolo
Data di Pubblicazione:
2018
Abstract:
Background: Thyroid nodules are very common in general population. Even if benign, they may require a treatment in case of symptoms or cosmetic concerns. In the last years, minimally invasive treatments alternative to surgery have been developed, in particular ultrasound (US) guided radiofrequency ablation (RFA). Methods: Twenty-four patients (9 males; 15 females; mean age 57.9 years) were treated and divided in two groups (A and B) according to the RFA needle used (18 gauge needle, AMICA; 17 gauge needle, COVIDIEN). Nodules and patients characteristics, together with procedural data were registered pretreatment and at 1-month follow-up. US visibility of the needle, volume of the nodules, symptoms and cosmetic concerns, complications were registered. Results: Visibility of the needle was not significantly different in the two groups (P=0.0787). At 1 month the mean volume of the nodules dropped from 37.1 to 25 mL in group A and from 23.2 to 15.4 mL in group B; shrinkage rate (36.9% and 39.5%, respectively) was not significantly different (P=0.3137). Symptoms decreased from 3.1 to 1.4 in group A and from 4 to 1.6 in group B: no significant differences in reductions were observed (P=0.3305). Cosmetic score decreased from 3.7 to 3.4 in group A and from 3.9 to 3.6 in group B: no significant differences in reductions were observed (P=0.96). Total complication rate (18.2% in group A vs. 23.1% in group B) did not showed significant differences (P=0.5049). Conclusions: The two systems used in our study resulted equivalent in terms of US needle visibility, efficacy, symptom/cosmetic relief, safety. More patients and a longer follow-up are necessary to confirm our results.
Tipologia CRIS:
14.a.1 Articolo su rivista
Keywords:
Ablation techniques; radiofrequency ablation (RFA); thyroid nodule
Elenco autori:
Francesco, Morelli; Anna Maria Ierardi, ; Giovanni, Pompili; Andrea, Sacrini; Pierpaolo, Biondetti; Salvatore Alessio Angileri, ; Giovanni, Montesano; Mario, Petrillo; Roberta, Giacchero; Gianlorenzo, Dionigi; Gianpaolo, Carrafiello
Link alla scheda completa:
https://iris.unime.it/handle/11570/3118677
Pubblicato in:
GLAND SURGERY
Journal
  • Dati Generali

Dati Generali

URL

http://dx.doi.org/10.21037/gs.2017.11.01