Skip to Main Content (Press Enter)

Logo UNIME
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Competenze e Professionalità
Logo UNIME

|

UNIFIND - Competenze e Professionalità

unime.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Usefulness of Combined Functional Assessment by Cardiac Magnetic Resonance and Tissue Characterization Versus Task Force Criteria for Diagnosis of Arrhythmogenic Right Ventricular Cardiomyopathy

Articolo
Data di Pubblicazione:
2016
Abstract:
Current task force criteria (TFC) of cardiac magnetic resonance (CMR) for the diagnosis of arrhythmogenic right ventricular cardiomyopathy (ARVC/D) were generated by comparing probands (mean age of 44 years) to healthy participants of the multi-ethnic study of atherosclerosis (mean age of 60 years). These age differences may be a selection bias because right ventricular end-diastolic volume index decreases 4.6% per decade. Moreover, fat infiltration and late gadolinium enhancement were not included. We evaluated the diagnostic accuracy of TFC using the same methodology used by the task force but comparing probands and age- and gender-matched healthy controls and considering also other morphofunctional and tissue abnormalities detected by CMR. Forty-seven probands with previous diagnosis of ARVC/D (excluding probands if CMR was used for diagnosis) were compared with 216 age- and gender-matched healthy controls. TFC had optimal specificity (100%) but poor sensitivity (20% for major and 13% for minor criteria). The presence of any pre- and post-contrast signal abnormalities had 100% specificity and 81% sensitivity. The best diagnostic accuracy (98%) was achieved by the combined evaluation of any right ventricular wall motion abnormality (excluding hypokinesia) with any signal abnormality (including left ventricular fat infiltration and late gadolinium enhancement) yielding a 100% specificity and 96% sensitivity. Left ventricular was involved in 45% of the probands. Current TFC for CMR presented optimal specificity but poor sensitivity to identify patient with ARVC/D. Signal and wall motion parameters of CMR should be considered together to achieve the best diagnostic accuracy for the diagnosis of ARVC/D.
Tipologia CRIS:
14.a.1 Articolo su rivista
Keywords:
Cardiology and Cardiovascular Medicine
Elenco autori:
Aquaro, Giovanni Donato; Barison, Andrea; Todiere, Giancarlo; Grigoratos, Chrysanthos; Ait Ali, Lamia; Di Bella, Gianluca; Emdin, Michele; Festa, Pierluigi
Autori di Ateneo:
DI BELLA Gianluca
Link alla scheda completa:
https://iris.unime.it/handle/11570/3106324
Pubblicato in:
THE AMERICAN JOURNAL OF CARDIOLOGY
Journal
  • Dati Generali

Dati Generali

URL

www.elsevier.com/locate/amjcard
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.5.0.0