Skip to Main Content (Press Enter)

Logo UNIME
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Competenze e Professionalità
Logo UNIME

|

UNIFIND - Competenze e Professionalità

unime.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Cyclic fatigue resistance of two nickel-titanium rotary instruments in interrupted rotation

Articolo
Data di Pubblicazione:
2017
Abstract:
Aim: To investigate the influence of interrupted rotation on cyclic fatigue of two nickel–titanium rotary instruments. Methodology: Cyclic fatigue of 300 new ProTaper Next size X1; X2 and Mtwo size 10, .04 taper; size 15, .05 taper; size 20, .06 taper and size 25, .06 taper instruments was tested in continuous or interrupted rotation. Fifty files of the same brand and size were randomly assigned to five groups (n = 10). Group 1 instruments were tested in continuous rotation; groups 2 and 3 in paused rotation for 1 s every 10 or 20 s, respectively; groups 4 and 5 in interrupted rotation for 5 s every 10 or 20 s, respectively. Cyclic fatigue was expressed in time to fracture (TtF) in an artificial canal with 60° angle and 5 mm radius of curvature. The fracture surface was examined with a scanning electron microscope (SEM). Data were evaluated by two-way analysis of variance. Results: Cyclic fatigue of groups 2 and 4 of ProTaper Next X2 and Mtwo size 25, .06 taper was significantly lower than that of group 1 of the same instruments (P < 0.01). ProTaper Next X2 had significantly reduced cyclic fatigue in groups 3 and 5 (P < 0.05). No differences were found by interrupting the rotation for 1 or 5 s in all instruments (P > 0.05). Fatigue of other instruments was not affected by interrupted rotation (P > 0.05). Conclusions: Interrupted rotation reduced cyclic fatigue resistance of ProTaper Next X2 and Mtwo size 25, .06 taper, especially when a higher number of interruptions was performed
Tipologia CRIS:
14.a.1 Articolo su rivista
Keywords:
Cyclic fatigue resistance; Interrupted rotation; Mtwo; NiTi fracture; ProTaper Next; Dentistry (all)
Elenco autori:
Pedullà, E; Lizio, ANGELO SERGIO; Scibilia, M.; Grande, N. M.; Plotino, G.; Boninelli, S.; Rapisarda, E.; LO GIUDICE, Giuseppe
Autori di Ateneo:
LO GIUDICE Giuseppe
Link alla scheda completa:
https://iris.unime.it/handle/11570/3085108
Pubblicato in:
INTERNATIONAL ENDODONTIC JOURNAL
Journal
  • Dati Generali

Dati Generali

URL

http://onlinelibrary.wiley.com/doi/epdf/10.1111/iej.12609
  • Informazioni
  • Assistenza
  • Accessibilità
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.5.0.0